Coopers Fire Ltd
Edward House
Penner Road
Havant
Hampshire PO9 1QZ
Tel: +44 (0)23 9245 4405
Fax: +44 (0)23 9249 2732
Email: john.bartlett@
coopersfire.com
Website: www.coopersfire.com
Contact: John Bartlett
rps no: 4496
Coopers Fire Ltd
Fire and smoke containment curtains
Following the patent of its Gravity Fail Safe Fire and Smoke Curtain in 1981, Coopers has been a market leader in fire and
smoke containment.
Introduction Coopers supplies,
installs, commissions, services and
maintains the complete SHEVS
(Smoke, Heat, Exhaust, Ventilation
Systems) package including
ventilation, containment and
intelligent building controls.
The innovative Coopers control
system allows full addressability,
monitoring and control.
Coopers engineers fully understand
current fire and smoke control
legislation, and work alongside
construction engineers and contractors
to produce safe, efficient systems to
suit any type of environment.
Authority BSI and LPCB quality
assurance, Warrington UAE
Certification for smoke and fire
curtains, and comprehensive BS
and EN tested product certification
including full compliance with
BS PAS 121: 2007.
DESCRIPTION
Coopers fire and smoke curtains
allow architects and designers
greater design freedom in their use
of open spaces. The range offers:
· Two hour FR fire curtain with two
hour fire shutter performance
· Four hour FR fire curtain with
four hour fire shutter performance
for overlapping curtains
30 minute and 60 minute
'Insulating Zone' fire curtains
with two and three hour FR
intensity
· Two hour FR horizontal fire
curtain for FR and/or radiation
· Wide area horizontal smoke
curtain 12 m x 12 m
· Virtual lift lobby fire curtain
which removes the need for fire
walls and doors
· ViiFire door that removes the
need for fire doors in doorways
and corridors
· ViiFire wall that allows architects
and designers to remove fire
walls
· ViiFire Serve which provides a
slim unobtrusive alternative to fire
shutters
FireMaster and SmokeStop
curtains remain retracted in steel
housings within the ceiling void,
deploying automatically only in the
event of fire or when triggered by an
alarm.
FireMaster curtains allow easy
escape for occupants and entry for
emergency services either through or
under the curtains, which quickly
reseal when penetrated. Features
include auto-retract and fully
addressable monitoring systems that
can be interfaced with dedicated fire
and smoke alarm systems with either
local or remote monitoring.
Systems are available with full
'Gravity Fail Safe' feature which
ensures a safe, controlled descent
in the event of a total power, wiring
or control failure.
Dimensions Units are available to
fit widths of up to 54 m and drops of
up to 12 m.
PERFORMANCE
FireMaster & ViiFire both achieve
four hour FR to BS 476: Part 22:
Clause 8 and/or one hour 'insulating
zone' and/or BS EN 1634: Part 1: 90
minutes FR as well as fully
complying to BS PAS 121: 2007.
Fitted horizontally it achieves two hour
FR to BS EN 364.
SmokeStop complies with
BS EN 12101 + CE Mark, or BS 7346:
Part 3.
SERVICES
Services to specifiers comprise full
design, manufacture, installation
and commissioning, national and
international site work, full
after-sales service and
maintenance.
Top left: ViiFire door (open and
closed)
Top right: FireMaster horizontal fire
curtain
Bottom left and right: FireMaster
vertical fire curtains
Above: SmokeStop vertical smoke
curtains with curved, 'invisible'