Coopers Fire Ltd
Fire and smoke containment curtains
Following the patent of its Gravity Fail Safe Fire and Smoke Curtain in 1981, Coopers has been a market leader in fire and 
smoke containment.
Introduction  Coopers supplies, 
installs, commissions, services and 
maintains the complete SHEVS 
(Smoke, Heat, Exhaust, Ventilation 
Systems) package including 
ventilation, containment and 
intelligent building controls.
The innovative Coopers control 
system allows full addressability, 
monitoring and control.
Coopers engineers fully understand 
current fire and smoke control 
legislation, and work alongside 
construction engineers and contractors 
to produce safe, efficient systems to 
suit any type of environment.
Authority  BSI and LPCB quality 
assurance, Warrington UAE 
Certification for smoke and fire 
curtains, and comprehensive BS
and EN tested product certification 
including full compliance with 
BS PAS 121: 2007.
DESCRIPTION
Coopers fire and smoke curtains 
allow architects and designers 
greater design freedom in their use 
of open spaces. The range offers:
·  Two hour FR fire curtain with two
 
hour fire shutter performance
·  Four hour FR fire curtain with  
 
four hour fire shutter performance  
 
for overlapping curtains 
 
30 minute and 60 minute  
 
 
'Insulating Zone' fire curtains  
 
 with two and three hour FR
 intensity
·  Two hour FR horizontal fire
 curtain for FR and/or radiation
·  Wide area horizontal smoke
 
curtain 12 m x 12 m
·  Virtual lift lobby fire curtain
 
which removes the need for fire  
 
walls and doors
·  ViiFire door that removes the  
 
need for fire doors in doorways   
 
and corridors
·  ViiFire wall that allows architects
 
and designers to remove fire  
 
 walls
·  ViiFire Serve which provides a  
 
slim unobtrusive alternative to fire 
 shutters
FireMaster and SmokeStop 
curtains remain retracted in steel 
housings within the ceiling void, 
deploying automatically only in the 
event of fire or when triggered by an 
alarm.
FireMaster curtains allow easy 
escape for occupants and entry for 
emergency services either through or 
under the curtains, which quickly 
reseal when penetrated. Features
include auto-retract and fully 
addressable monitoring systems that 
can be interfaced with dedicated fire 
and smoke alarm systems with either 
local or remote monitoring.
Systems are available with full 
'Gravity Fail Safe' feature which
ensures a safe, controlled descent 
in the event of a total power, wiring
or control failure.
Dimensions  Units are available to 
fit widths of up to 54 m and drops of 
up to 12 m.
PERFORMANCE
FireMaster & ViiFire both achieve 
four hour FR to BS 476: Part 22:
Clause 8 and/or one hour 'insulating
zone' and/or BS EN 1634: Part 1: 90
minutes FR as well as fully
complying to BS PAS 121: 2007. 
Fitted horizontally it achieves two hour
FR to BS EN 364.
SmokeStop complies with 
BS EN 12101 + CE Mark, or BS 7346: 
Part 3.
SERVICES
Services to specifiers comprise full 
design, manufacture, installation 
and commissioning, national and 
international site work, full
after-sales service and 
maintenance.
Top left: ViiFire door (open and 
closed)
Top right: FireMaster horizontal fire 
curtain
Bottom left and right: FireMaster 
vertical fire curtains
Above: SmokeStop vertical smoke 
curtains with curved, 'invisible' 
ceiling interface