The Benchmark Karrier Panel System is an alternative building method to the Benchmark Connect system and is a unique insulated panel that has been specifically designed and tested to support Benchmark's ranges of façades. It can be laid vertically and horizontally, with or without a top hat section to suit the Benchmark façade. The system provides excellent weather resistance, thermal, acoustic, fire and structural performance. The Benchmark Karrier Panel is a metal faced insulated panel that makes the building watertight, removing the façade from the critical path and enabling internal fit out to start sooner.

Benefits:

  • A wide range of through fix and secret fix Benchmark façades is available.
  • Multiple size façade finishes, very low limitations.
  • Suitable for buildings of any height.
  • Simple and fast to construct.
  • Easily accommodates openings, penetrations and complex façades.
  • Simple integration with doors, windows, glazing, louvres and traditional construction materials.
  • Lifetime insulation continuity, thermal performance and airtightness (less than 5 m³/hr/m²) certainty.
  • Independently tested system, including CWCT external building envelope.
  • Available with the Total Benchmark Guarantee.
  • Manufactured and supplied under a quality system certified to BS EN ISO 9001: 2000.
  • Manufacturing plants are ISO 14001 (Environmentally) accredited.

Standard product features

Design Wall Series:

- Fire resistance:

FIREsafe approved by the Loss Prevention Certification Board (LPCB) to LPS 1181 Grade EXT-B. External and internal faces of the panels are Class 0 in accordance with the Building Regulations when tested to BS 476-6: 1989 (Fire propagation for products) and BS 476-7: 1997 (Surface spread of flame of products) and have a European fire classification of B-s2, d0. The external steel facing of the Render façade is Class 3 when tested to surface spread of flame to BS476-7: 1987 (Surface spread of flame of products) and has a European fire classification of B-s2, d0.

- Acoustic properties:

All panels have a single figure weighted sound reduction, Rw = 24 dB.

Options

Façade:

Consult manufacturer's literature for further details relating to technical characteristics of façade type chosen.

- Cementitious Board:

Maximum module sizes available after trimming by fabricator (including 10 mm joint) are 2500 x 1250, 3100 x 1250 or 3100 x 1500 mm. Face panel thickness: 8 or 12 mm.

- Ceramic Granite:

Maximum module 1206 mm length x 606 mm height (inclusive of 8 mm joint) and maximum actual panel size 1198 mm length x 598 mm height. Smaller bespoke sizes are available. Face panel thickness: 12 mm maximum.

- Ceramic Tile:

Five different tile sizes available: 400 x 200, 500 x 250, 500 x 280, 600 x 250 or 600 x 280 mm. Face panel thickness: 15 mm maximum.

- Design Wall Series, Curve:

Standard length: 1.8–17 m. Panels less than 1.8 m long can be supplied and are subject to an additional charge. These panels cannot be end lapped.

- Design Wall Series, Evolution:

Standard length: 1.8–12 m. Panel lengths up to 17 m are available. Panels less than 1.8 m long can be supplied and are subject to an additional charge. These panels cannot be end lapped.

- Design Wall Series, Louvre:

Standard lengths 1.8–17 m. Panels less than 1.8 m long can be supplied and are subject to an additional charge. These panels cannot be end lapped.

- Design Wall Series, Render:

Standard lengths 1.8–8 m. Panel lengths up to 16 m are available. Panels less than 1.8 m long can be supplied and are subject to an additional charge. These panels cannot be end lapped.

- Glass:

  • The coloured glass is available in virtually any colour BS, RAL or matched to other colours on request subject to minimum production quantities. The mirrored glass is available as an option.
  • Standard module 1206 mm length x 606 mm height (inclusive of 8 mm joint) and maximum actual panel size 1198 mm length x 598 mm height. Other bespoke sizes are available. Face panel thickness: 12 mm maximum.

- Metallic:

Some cassette options have limited finishes available – consult literature for details.

- Metallic mesh:

  • The mesh can be powder coated in virtually any colour BS, NCS and RAL or matched to other colours on request subject to minimum production quantities.
  • Maximum module size 2500 x 1250 mm. Smaller bespoke sizes are available.
  • Consult manufacturer's literature for thickness details.

- Timber:

  • Lengths can range from 1.2–6.0 m but can vary. Contact the Benchmark Technical Department for further information.
  • Face panel thickness: 21 mm (Siberian Larch, Thermowood and Sweet Chestnut), 17 mm (Accoya and Western Red Cedar).

- Wood:

Standard modules are 3050 mm length x 1530 mm height and 2550 mm length x 1860 mm height (excluding the 10 mm joint). Sizes are tailored to the build option, contact the Benchmark Technical Service Department for further information. Face panel thickness: 8, 10 or 13 mm.

Product specification

An important note about specifying

Manufacturer

Name:

Kingspan Insulated Panels

Tel:

+44 (0)1352 716100

Product reference

Karrier Panel System

Frame

[Lightweight steel]
-
From Kingspan Profiles & Sections, contact manufacturer for details.
[Purlin and rail system]
-
From Kingspan Structural Products, contact manufacturer for details.
[As drawing]

Karrier Panel

[Not required]
-
When specifying Design Wall Series façades.
[45 mm]
-
U-value: 0.54 W/m²K.
[60 mm]
-
U-value: 0.35 W/m²K.
[70 mm]
-
U-value: 0.30 W/m²K.
[80 mm]
-
U-value: 0.26 W/m²K.
[100 mm]
-
U-value: 0.21 W/m²K.
[120 mm]
-
U-value: 0.18 W/m²K.
[140 mm]
-
U-value: 0.15 W/m²K
[150 mm]
-
U-value: 0.14 W/m²K.

Façade

 - Type:
[Cementitious Board]
[Ceramic Granite]
[Ceramic Tile]
[Design Wall Series, Curve]
-
No Karrier panel required.
[Design Wall Series, Evolution]
-
No Karrier panel required.
[Design Wall Series, Louvre]
-
No Karrier panel required.
[Design Wall Series, Render]
-
No Karrier panel required.
[Glass]
[Metallic, hook-on cassette]
[Metallic, interlocking plank]
[Metallic, recessed fix cassette]
[Metallic, shingle]
[Metallic, tray]
[Metallic mesh, 110]
[Metallic mesh, Barcelona]
[Metallic mesh, Bilbao]
[Metallic mesh, Bilbao 2]
[Metallic mesh, Crescent]
[Metallic mesh, Malaga]
[Metallic mesh, Pisa]
[Metallic mesh, Tirol]
[Timber, Accoya]
[Timber, Siberian Larch]
[Timber, Sweet Chestnut]
[Timber, Thermowood]
[Timber, Western Red Cedar]
[Wood, fire resistant]
[Wood, standard]
 
 - Thickness:
[ ______ ]
 
 - Colour/ Finish:
[ ______ ]
 

Accessories

[ ______ ]

Manufacturer details

Greenfield Business Park No 2,
Greenfield,
Holywell,
Flintshire, CH8 7GJ
Tel +44 (0)1352 716100
Fax +44 (0)1352 710161
NBS Plus
RIBA CPD