Home > Companies > VELUX Company Ltd > GPL manually operated, top-hung roof window, with GIL sloping fixed windows below, combination installation

Manually operated, top hung roof window with additional lower fixed element for combination installations on roof pitches between 15–55° (75° with special springs).

Fixed elements are installed in combination side by side to create panoramic views. The fixed windows are installed directly below the roof windows.

Combination flashings are modular meaning there is no limit to the overall size of the group, but the minimum distance between windows side by side is 100 mm.

Ventilation, exterior maintenance and cleaning is all via the roof window.

Features:

  • Top-hung window opens to any position up to 45° to allow panoramic, uninterrupted views.
  • Meets requirements for emergency escape.
  • Additional fixed elements beneath offer a great view while standing and when seated.

Operation:

  • The window is opened by means of a handle placed at the bottom sash.
  • Sash can also be rotated 180° and locks in place for the ease of cleaning of the outer pane.

Warranty:

  • Ten-year guarantee for windows and panes.
  • Three-year guarantee for electrical items and blinds.

Options

Glazing:

- Code 60:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.62.
  • Total solar energy transmittance (g): 0.30.

- Code 66:

  • Thermal performance (U-value): 1.0 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 70:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.68.
  • Total solar energy transmittance (g): 0.46.

Configuration:

The number of roof windows must be the same as the number of lower fixed windows; roof windows and lower fixed windows must be the same width.

Flashing:

Flashings are available in materials and finishes to match roof window cladding.

  • Code EKL + ETL: For standard installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate; Roof pitches from 15–90°.
  • Code EKW + ETW: For standard installation into flat and profiled roofing materials up to 120 mm thick, including profiled sheeting and interlocking slates. Roof pitches from 15–90°.
  • Code EKN + ETN: For recessed installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate; Roof pitches from 15–90°.
  • Code EKJ + ETJ: For recessed installation into flat and profiled roof materials up to 90 mm thick, including profiled sheeting and interlocking slates; Roof pitches from 20–90°.
  • Code ZWC: Window profile set to be used in conjunction with on-site weathering for non-standard roofing materials. For further details please contact VELUX.

NBS Specification

NBS Create logo
This product is associated with the following NBS Create clause:
45-25-99/390 Wood frame roof window units

NBS Specification

NBS Buliding logo
This product is associated with the following NBS clauses:

Product specification

An important note about specifying

Manufacturer

Name:

VELUX Company Ltd

Tel:

+44 (0)1592 778225

Product reference

GPL manually operated, top-hung roof window, with GIL sloping fixed windows below, combination installation

Roof pitch

[ ______ ]

Number of roof windows

[ ______ ]

Number of fixed lights

[ ______ ]

Distance between side frames

[100 mm]
-
Standard frame gap.
[120 mm]
[140 mm]
[160 mm]

Window

 - Roof window code:
[GPL MK04]
-
Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m².
[GPL MK06]
-
Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m².
[GPL MK08]
-
Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m².
[GPL PK08]
-
Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m².
[GPL PK10]
-
Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m².
[GPL SK06]
-
Standard size 1140 mm wide x 1178 mm high, effective daylight area 0.95 m².
[GPL UK04]
-
Standard size 1340 mm wide x 978 mm high, effective daylight area 0.91 m².
[GPL UK08]
-
Standard size 1340 mm wide x 1398 mm high, effective daylight area 1.40 m².
[GPL FK08]
-
Non-standard size 660 mm wide x 1398 mm high, effective daylight area 0.58 m².
[GPL MK10]
-
Non-standard size 780 mm wide x 1600 mm high, effective daylight area 0.85 m².
[GPL PK04]
-
Non-standard size 942 mm wide x 978 mm high, effective daylight area 0.60 m².
[GPL PK06]
-
Non-standard size 942 mm wide x 1178 mm high, effective daylight area 0.75 m².
[GPL SK08]
-
Non-standard size 1140 mm wide x 1398 mm high, effective daylight area 1.16 m².
[GPL SK10]
-
Non-standard size 1140 mm wide x 1600 mm high, effective daylight area 1.35 m².
 
 - Fixed lower window code:
[GIL MK34]
-
Standard size 780 mm wide x 920 mm high; effective daylight area 0.44 m².
[GIL PK34]
-
Standard size 942 mm wide x 920 mm high; effective daylight area 0.56 m².
[GIL SK34]
-
Non-standard size 1140 mm wide x 920 mm high; effective daylight area 0.70 m².
[GIL UK34]
-
Non-standard size 1340 mm wide x 920 mm high; effective daylight area 0.85 m².
 

Finish

 - Internal frame and sash:
[White Painted – Code 2]
[Lacquered Natural Pine – Code 3]
 
 - External cladding:
[Grey aluminium; colour reference NCS S-7500-N - Code 0]
[Untreated copper – Code 1]
[Titanium zinc – Code 3]
[Painted aluminium – Code 8, colour]
-
Insert RAL or NCS colour reference.
 

Glazing

[60]
-
6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 6 mm toughened outer pane with easy to clean and low-e coatings.
[66]
-
6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings.
[70]
-
6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.

Blind

 - Upper roof window:
[Blackout blind – Code DKL]
[Blackout energy blind – Code FHC]
[Duo blackout blind – Code DFD]
[Flying pleated blind – Code FHL]
[Roller blind – Code RFL]
[Roman blind – Code FHB]
[Solar powered blackout blind – Code DSL]
[Solar powered blackout energy blind – Code FSC]
[Solar powered pleated blind – Code FSL]
[Solar powered roller blind – Code RSL]
[Venetian blind – Code PAL]
 

   Colour:

[Not applicable]
[As schedule ___]
-
Refer to VELUX Blinds and Shutters brochure for available colours and patterns.
 
 - Lower Fixed window:
[Not required]
[Blackout blind – Code DKL]
[Blackout energy blind – Code FHC]
[Duo blackout blind – Code DFD]
[Flying pleated blind – Code FHL]
[Roller blind – Code RFL]
[Roman blind – Code FHB]
[Solar powered blackout blind – Code DSL]
[Solar powered blackout energy blind – Code FSC]
[Solar powered pleated blind – Code FSL]
[Solar powered roller blind – Code RSL]
[Venetian blind – Code PAL]
 

   Colour:

[Not applicable]
[As top-hung]
[As schedule ___]
-
Refer to VELUX Blinds and Shutters brochure for available colours and patterns.
 

Energy efficient installation

[Insulation Collar – Code BDX 2000]
-
Not compatible with E*N and E*J flashings. Includes BFX.
[Underfelt Collar – Code BFX 1000]
[Vapour Barrier Collar – Code BBX 0000]

Flashing

[EKL + ETL]
-
For standard installation into slate up to 8 mm thick; roof pitch 15–90°.
[EKW + ETW]
-
For standard installation into tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting.
[EKN + ETN]
-
For recessed installation into slate up to 8 mm thick; roof pitch 20–90°.
[EKJ + ETJ]
-
For recessed installation into tile up to 120 mm thick; roof pitch 20–90°.
[ZWC]
-
For standard installation where an on-site flashing is required; roof pitch 15–90°.

Accessories

[None]
[Locking handle – code 028321]

Manufacturer details

Woodside Way,
Glenrothes,
Fife, KY7 4ND
Tel +44 (0)1592 778225
Fax +44 (0)1592 776980
NBS Plus
NBS National BIM Library